Friday, August 4, 2017

Sill Plate Termite Shield

Sill Plate Termite Shield Images

W FlooR Foundations - The Engineered Wood Association
Avoided with raised wood floor foundations. On The Upgrade. Homebuyers appreciate features of a raised foundation – a front porch, Treated Sill Plate (best practice) Termite Shield (optional) Reinforced Masonry Vapor Retarder (best practice) Footing ... Fetch Here

Photos of Sill Plate Termite Shield

If You Have An Interest In Mastering A Particular
2 If you have an interest in mastering a particular competency or class of competencies, share this interest with the House Leader who will then begin to think ... Return Document

Sill Plate Termite Shield

31 31 00 (02360) Soil Treatment - WBDG
31 31 00 (02360) - 1 When used in combination with a termite flashing shield, a rigid flashing between the sill plate and the foundation wall, the effectiveness of the system may be increased. If the termites do find an alternate ... Read More

Pictures of Sill Plate Termite Shield

Materials List - E Log Homes
Materials List 1. Pressure treated sill plate; Termite shield / Interior partition framing with double top plate and single bottom plate; 2x6 framing where necessary for plumbing walls Install pressure treated sill plate and termite 2. Install first floor system framing w/bridging. ... Get Document

Photos of Sill Plate Termite Shield

INSULATING FOUNDATION AND FLOORS - University Of Kentucky
In termite-prone areas, the sill plate of the building to further inhibit termite infestation. The termite shield should extend beyond other building materials to force termites into an ... Get Document

Sill Plate Termite Shield

Insulating Foundation And Floors - Habitat For Humanity
Insulating Foundation and Floors they should be installed continuously under the sill plate of the building to further inhibit termite infestation. The termite shield should extend beyond other building materials to ... Visit Document

Sill Plate Termite Shield

Sample Specifications For New Single Family Detached Homes
Sample Specifications For New Single Family Detached Homes To assist you, section and tables references from the Kentucky Residential IRC Code sill plate also serves as a termite shield; therefore, if 12" blocks are used, the sill plate will need ... Fetch Content

Images of Sill Plate Termite Shield

MOISTURE AND AIR LEAKAGE CONTROL - NREL
Alternative to the termite shield. Install termite shields continuously under the sill plate of the building. While not 100 percent effective, the termite shield may deter or delay widespread infestation and may also force termites into an exposed area where they ... Retrieve Full Source

Sill plate - Wikipedia
A sill plate or sole plate in construction and architecture is the bottom horizontal member of a wall or building to which vertical members are attached. ... Read Article

Images of Sill Plate Termite Shield

LIBERTY CENTER - Kierconstructioncorp.com
Sealant p.t. sill plate (refer to structural for anchorage) sealant termite shield note: refer to foundation plan for size and details base as scheduled ... Fetch Full Source

Photos of Sill Plate Termite Shield

Weather Shield
And sill for improved appearance and performance PRE-HUNG molds, fungus, termite and other insect attack. Low-Maintenance Clad Frames All of our doors come Weather Shield windows. Our thick, extruded aluminum cladding is three times stronger than the competitors roll-form cladding and ... Visit Document

Do You Know What A Termite Shield Is - YouTube
Do You Know What a Termite Shield Is HICarolina. Loading Bottom Sill Flashing - Slab to Bottom plate connection - Duration: 1:57. Matt Risinger 91,578 views. Termite Shield Breach in a Brisbane Home - Duration: ... View Video

Pictures of Sill Plate Termite Shield

Chart - Puc.state.nh.us
Insulation can give termites access, so be sure to provide a termite shield (Figure 8). membrane (termite shield) between the sill plate and foundation (Figure 8). Figure 8 chart.PDF Author: gaill ... Document Retrieval

Photos of Sill Plate Termite Shield


Has been applied and termite shield 3. service . and sill plate are installed 4. final . 3.framing after plumbing and hvac . are installed ... View Doc

Images of Sill Plate Termite Shield

Clayton County Community Development Department
Clayton County Community Development Department 1. Gable stud 2. Collar beam 3. Ceiling joist 4. Double plate 22. Entrance canopy 23. Garage cornice 24. Fascia Sill plate 47. Backfill 48. Termite shield 49. Window well wall 50. Grade line 51. Basement sash 52. ... Fetch Doc

Sill Plate Termite Shield

Light Wood Framing #1 - Mjobrien Architect
Light Wood Framing #1 References •Graphic Guide to Frame Construction, Rob • This termite shield makes the termites leave the cell foam to seal out drafts between the shield and the sill plate. • The sill plate MUST be rot resistant wood, and is bolted to the foundation wall at 4 ... Retrieve Document

Images of Sill Plate Termite Shield

Eco Red Shield Wood SpecificationNov2016
Building code requirements for use as Sill Plate, equivalence to Fire Retardant Treated Wood (FRTW) as Code compliant wood‐rot decay and termite resistance, above ground attached to Eco Red Shield Wood SpecificationNov2016.docx ... Get Document

Sill Plate Termite Shield Images

INSTALLATION RECOMMENDATIONS FOR STYROFOAM BLUEGUARD Exterior ...
Exterior Foundation, Interior Crawl Space, Under Slab new homes/ remodeling foundations slabs sills attics If a sill termite shield/flashing is not installed, up to the sill plate. If required by local code officials or your pest ... Fetch Full Source

Sill Plate Termite Shield Images

Technical Guide 2-1-2010 Edition - With Technical Design ...
Technical Design & Finishing Guide NOTE: Foam rip may need to be protected with a termite shield. Alternative materials may be substituted for the foam rip as required. BEND FRONT TAB OF JOIST STRAP DOWN TO SILL PLATE AND NAIL TO SILL PLATE ... Read More

Framing (construction) - Wikipedia
They are supported on a bottom plate or foundation sill and in turn support the top plate. Studs usually consist of 1.5 by 3.5 inches (38 mm × 89 mm) Termite shield; References Canada Mortgage and Housing Corporation (2005). Canadian Wood-Frame House Construction. ISBN 0-660 ... Read Article

Bottom Sill Flashing - Slab To Bottom plate Connection
In this video I'm showing the best practice way to seal the bottom plates of a home built on a concrete slab. You'll see a Carlyle through wall flashing with ... View Video

Photos of Sill Plate Termite Shield

Laminated Copper Termite Barrier - BuildSite
Laminated Copper Termite Barrier ACQ treatment corrodes Install YorkShield 106 TS between the foundation and the sill plate with the copper side up. YORKSHIELD 106 TS™ SHOULD BE USED AS A TERMITE SHIELD ONLY, NOT AS FLASHING. ... Retrieve Full Source

Sill Plate Termite Shield Photos

Alabama Builder’s Field Guide - Southface Energy Institute
Termite shield Interior foam 1 to 2 inch extruded polystyrene Interior batt R-11 to Termite shield Pressure-treated sill plate Gravel and drain tile Plastic vapor barrier 4 5 Alabama Builder’s Field Guide ... Access This Document

Sill Plate Termite Shield Images

Single And Two-Family Residential Construction Requirements
Single and Two-Family Residential Construction Requirements 17. Termite shield: This will allow the Inspector to check the termite shield and type of plate/sill used. 2. ... Access This Document

No comments:

Post a Comment